Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-370
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5CBR700
RBU response message
timeout error during EEPROM
R/W.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5CBS000
RBU communication timeout
error when EEPROM R/W.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5CBS100
RBU connection sequence
error when EEPROM R/W.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5CBS200
RBU connection MI error when
EEPROM R/W.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5CS0200
The shutter did not close under
closing shutter command(MS1
Dark). Half of close(MS2
Light).
1. Check that some object disturb to
close shutter
2. Check the motor home position
sensor is under the nomal if error still
occures without disturbed object
5CS1200
The shutter did not close under
closing shutter command(MS1
Dark). Opend status(MS2
Dark).
1. Check that some object disturb to
close shutter
2. Check the motor home position
sensor is under the nomal if error still
occures without disturbed object
5CS1400
Detect substance in the shutter
when shutter was closed with
close command(HS4 Dark).
1. Check substance inside of the shutter
5CS3200
The moter home position
sensor (MS1 & MS2) had
problem(MS1 Light & MS2
Dark).
1. error occurred by motor home
position sensor´s problem
2. Check the motor home position
sensor
3. Check defect of MS1 and MS2
5CSSE00
Sequence number duplicated
with close command.
1. Check the detail sequence number of
bulk sending command
5CUS100
USB sequence number
duplicate error when EEPROM
R/W.
1. Restart over AP-SP
5CUS300
USB command data length
error when EEPROM R/W.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5D00100
GS801 light jam error during
Initialize .
1. Open the upper unit.
2. Open the customer service module
(CSM)
3. Open the BC(5)
4.Remove notes and substance in the
Front Transport Path(4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance