Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-366
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5BARA00
BM notes revert message
timeout error when auto
recoveryduring Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5BARB00
Remain notes process
message timeout error when
auto recoveryduring Retract
TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5BARJ00
Message timeout error while
Stop Ready during Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5BAS800
Separate count is more than
Remain count when updating
notes count duringduring
Retract TE.
1. Operate to initialize BRM(Recovery)
5BBH100
RC1 EEPROM read error
during Retract TE.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5BBH200
RC2 EEPROM read error
during Retract TE.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5BBH300
RC3 EEPROM read error
during Retract TE.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5BBH400
RC4 EEPROM read error
during Retract TE.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5BBH500
RC5 EEPROM read error
during Retract TE.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5BBH600
RC1 EEPROM Write error
during Retract TE.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5BBH700
RC2 EEPROM Write error
during Retract TE.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5BBH800
RC3 EEPROM Write error
during Retract TE.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5BBH900
RC4 EEPROM Write error
during Retract TE.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5BBHA00
RC5 EEPROM Write error
during Retract TE.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization