Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-217
Code
Problem Description
Troubleshooting
572NL00
Case of below is semi OK.
When RC2 setting count is 0
during withdrawal, separation
is set to sop. Actual count is
more than remain count,
remain count is more than
require count..
1. Check RC2 actual count and SPL
screen count.
2. Setting RC2 count match actual
count.
3. Operate to initialize BRM(Recovery)
572R100
RC2 message timeout error
during operation ready in the
Withdrawal .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
572R200
RC2 message timeout error
during transation operation in
the Withdrawal .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
572R300
RC2Message timeout error
during postprocessing of
Withdrawal Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
572RJ00
RC2 message timeout error
during Stop Ready in the
Deposit Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
572S100
Undefined return value of RC2
during Withdrawal .
1. Operate to initialize BRM(Recovery)
572S200
Undefined command of RC2
during Withdrawal .
1. Operate to initialize BRM(Recovery)
572S300
An inoperable command,
Withdrawal Ready is issued to
RC2 during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
572SZ00
Failure to separate required
Notes in the RC2 while
withdrawal stops to sepatate 0
count(NO available RC
cassette to separate).
1. Check the remained count in the RC
5730500
GS305 light jam error during
Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
5731100
GS301 sensor jam during
Withdrawal .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance