Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-90
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
534GC00
Encoder Sensor(GS407) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Deposit End.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS407 works fine if
there is nothing jammed.
534GG00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
534GH00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
534J300
Failure to RC4 full check
during Deposit End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Check the stage status after open the
recycle cassette(D)
5. Check contamination status of the
GS412 sensor.
534R100
RC4 message timeout error
during operation ready in the
Deposit End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
534R200
RC4 message timeout error
during transation operation in
the Deposit End .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
534R300
RC4 message timeout error
during postprocessing of
Deposit End Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
534S100
Undefined return value of RC4
during Deposit End.
1. Operate to initialize BRM(Recovery)
534S200
Undefined command of RC4
during Deposit End.
1. Operate to initialize BRM(Recovery)
5350500
GS505 Light Jam during
Deposit End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(18)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).