Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-452
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5K0DU00
Error of failure to synchronizing
recognition during Withdrawal
Reject.
1. Operate to initialize BRM(Recovery)
5K0DV00
Error of failure to synchronizing
recognition during Withdrawal
Reject.
1. Operate to initialize BRM(Recovery)
5K0DW00
Error of failure to synchronizing
recognition during Withdrawal
Reject.
1. Operate to initialize BRM(Recovery)
5K0DX00
Error of failure to synchronizing
recognition during Withdrawal
Reject.
1. Operate to initialize BRM(Recovery)
5K0DY00
Error of failure to synchronizing
recognition during Withdrawal
Reject.
1. Operate to initialize BRM(Recovery)
5K0F100
GM001 motor step out return
error during Withdrawal Reject.
1. Open the upper unit
2. Check the Front Transport Path(4)
knob rotates softly
3.Check remained Notes and substance
in the upper Transport Path
4. Check the sensor GS804 status
5K0F200
GM002 motor step out return
error during Withdrawal Reject.
1. Open the upper unit
2. Check the Rear Transport Path(8)
knob rotates softly
3.Check remained Notes and substance
in the upper Transport Path
4. Check the sensor GS007 status
5K0F400
GM004 motor step out return
error during Withdrawal Reject.
1. Open the lower unit
2. Check the knob rotates in the Mid
Transport Path(20)
3. Check the notes and substance
inside of the Mid Transport Path
4. Check the sensor GS023
5K0F500
Decreased encoder count of
GM001 moter less than
previous values during
Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
5K0F600
Decreased encoder count of
GM002 moter less than
previous values during
Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
5K0F700
Decreassed encoder count of
GM004 moter less than
previous values during
Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
5K0G100
Failure to 3 Way Gate 0
degree mode conversion
during Withdrawal Reject.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
5K0G200
Failure to 3 Way Gate 120
degree mode conversion
during Withdrawal Reject.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
5K0K100
Erro of failure to duplicate
serial number during
Withdrawal Reject
1. Check the duplicate note and remove
the note.