Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-512
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5QA2G00
Status of remaining notes on
the return Path(GS614) before
the operation during Retract
CSM + TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5QA2H00
Status of remaining notes on
the return Path(GS618) before
the operation during Retract
CSM + TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5QA2J00
Status of remaining notes on
the return Path(GS619) before
the operation during Retract
CSM + TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5QA2K00
Status of remaining notes on
the return Path(GS703) before
the operation during Retract
CSM + TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5QA2M00
Status of remaining notes on
the return Path(GS031) before
the operation during Retract
CSM + TE.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5QA2N00
Status of remaining notes on
the return Path(GS032) before
the operation during Retract
CSM + TE.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5QA2P00
Status of remaining notes on
the return Path(GS033) before
the operation during Retract
CSM + TE.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance