Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-289
Code
Problem Description
Troubleshooting
5A01300
GS003 dark jam error during
Retract CSM.
1. Open the upper unit.
2. Open TE(12)
3. Open the Rear Transport Path(6)
4. Remove the notes and substance on
the Rear Transport Path(6)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A01400
GS004 dark jam error during
Retract CSM.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove the cassette not received(9)
4. Remove substance in the Rear
Transport Path(8)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5A01500
GS005 dark jam error during
Retract CSM.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A01600
GS006 dark jam error during
Retract CSM.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove the cassette not received(9)
4. Remove substance in the Rear
Transport Path(7)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5A01A00
GS021 dark jam error during
Retract CSM.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A01B00
GS022 dark jam error during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove substance in the Mid
Transport Path(19)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5A01G00
GS614 dark jam error during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove substance in the CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance.