Code
Problem Description
Troubleshooting
564GB00
Encoder Sensor(GS407) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Withdrawal Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS407 works fine if
there is nothing jammed.
564GC00
Encoder Sensor(GS407) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Withdrawal Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS407 works fine if
there is nothing jammed.
564GD00
Detect GS401, GS402 as
excessive notes during
Withdrawal Ready
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Remove note.
564GE00
Detect GS408(separate
pressure) as excessive note at
FM homeposition movement
durting Withdrawal Ready
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Remove note.
564J200
RC4 empty during Withdrawal
Ready.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Check the notes remain after Open
the recycle cassette door(D)
5. Fill up the Notes if there are no notes
6. Check whether the sensor is
contaminated if there are Notes.
564R100
RC4 message timeout error
during operation ready in the
Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
564R200
RC4 message timeout error
during transation operation in
the Withdrawal Ready .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
564R300
RC4 message timeout error
during postprocessing of
Withdrawal Ready Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
564RJ00
RC4 message timeout error
during Ready Stio in the
Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
564S100
Undefined return value of RC4
during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
564S200
Undefined command of RC4
during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)