Code
Problem Description
Troubleshooting
5BAAC00
Status of RJC full before the
operation during Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated or not if a cassette is
empty.
5BAAD00
Status of UTC1 full before the
operation during Retract TE.
1. Open the upper unit
2. Open the cassette not received(9)
3. Check the cassette not received(9) is
full
5BAAE00
Status of UTC2 full before the
operation during Retract TE.
1. Open the upper unit
2. Open the forge note cassette(10
3. Check the forge note cassette(10) is
full
5BAAF00
Status of RC empty before the
operation during Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the residual notes quantity in
the recycle cassettes(A~E)
5BAAG00
Unused status of RC to store
doubted notes before the
operation during Retract TE.
1. Check to load RC which receipts
doubted notes
2. Operate to initialize BRM(Recovery)
3. Excluding RC removed from doubted
cassette when you use a TE for the
test
5BAAH00
Removal status of RC to store
Retracted CSM notes before
the operation during Retract
TE.
1. Check that RC for retracting Notes is
equipped
2. Operate to initialize BRM(Recovery)
3. Excluding RC removed from
Retracted cassette when you use a TE
for the test
5BAAJ00
Removal status of RC to store
abnormal serial number before
the operation duringRetract TE
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the recycle cassette
load/removal
5BAAK00
Retracting cassette set UTC1
or UTC2 in unused UTC before
to operation during Retract TE
1. Check the SP setting.
2. Restart over AP-SP
3. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5BAE100
Received operation command
without Initial Info Set during
Retract TE.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5BAE200
Status on not operation
receiption command during
Retract TE.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5BAE300
Received operation command
without System Info Read
during Retract TE.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization