5BA2300
Status of remaining notes on
the return Path(GS003) before
the operation during Retract
TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove notes and substance in the
Rear Transport Path(6)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5BA2400
Status of remaining notes on
the return Path(GS004) before
the operation during Retract
TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9)
4. Remove notes and substance in the
Rear Transport Path(8)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5BA2500
Status of remaining notes on
the return Path(GS005) before
the operation during Retract
TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5BA2600
Status of remaining notes on
the return Path(GS006) before
the operation during Retract
TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9)
4. Remove notes and substance in the
Rear Transport Path(8)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5BA2A00
Status of remaining notes on
the return Path(GS021) before
the operation during Retract
TE.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5BA2B00
Status of remaining notes on
the return Path(GS022) before
the operation during Retract
TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the banknotes and the
foreign substance from the reject
cassette (19)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5BA2G00
Status of remaining notes on
the return Path(GS614) before
the operation during Retract
TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance