Code
Problem Description
Troubleshooting
5D8HG36
Error of recognized mode
during receiving BCU mode
command in the Initialize .
1. Check to the recoginzed mode
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
5D8HG37
Error of transaction setting
during receiving BCU mode
command in the Initialize .
1. Check to the transaction setting
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
5D8R100
BC message timeout error
during operation ready in the
Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D8R200
BC message timeout error
during transaction operation in
the Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D8R300
BC message timeout error
during postprocessing to
Initialize Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D8R900
BC message timeout error
during Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D8S100
Receive abnormal MI from BC
during Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D8S200
Receive abnormal BCC from
BC during Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D8S400
BC received Ect disorder
during Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D8S900
Receive retry error from BC
during Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D91300
RJC GSA03 dark jam error
during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Open the reject cassette(21)
4. Remove notes and substance in the
reject cassette(21)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance