Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-425
Code
Problem Description
Troubleshooting
5E02A00
Error occurred by the notes
remained on the GS021 during
Withdrawal Ready before
opening shutter.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5E02B00
Error occurred by the notes
remained on the GS022 during
Withdrawal Ready before
opening shutter.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the banknotes and the
foreign substance from the reject
cassette (19)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5E02G00
Error occurred by the notes
remained on the GS614 during
Withdrawal Ready before
opening shutter.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5E02H00
Error occurred by the notes
remained on the GS618 during
Withdrawal Ready before
opening shutter.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5E02J00
Error occurred by the notes
remained on the GS619 during
Withdrawal Ready before
opening shutter.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5E02K00
Error occurred by the notes
remained on the GS703 during
Withdrawal Ready before
opening shutter.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5E02M00
Error occurred by the notes
remained on the GS031 during
Withdrawal Ready before
opening shutter.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance