Code
Problem Description
Troubleshooting
I430F
[Deposit Count/Check] Sensor
fault when preparing for
separation of media.
1. Check the inside of the Bundle(1).
2. Remove the notes and alien materials
in the Bundle entry part (BDS01,
BDS02) sensors.
3. If no alien material exists, check
whether the sensor is polluted.
I4312
[Deposit Count/Check] Fault of
receiving media returned due to
low-speed moving path up.
1. Open the door at the Bundle side and
remove the residual media.
2. Check and remove the alien materials
in the Bundle low-speed wheel position
control (BDS14) sensor.
3. If no alien material exists, check
whether the sensor is polluted.
4. Initialize the device.
I4315
[Deposit Count/Check]Fault of
calling a undefined command from
Bundle.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4318
[Deposit Count/Check]Fault of
performing a undefined process
flow from Bundle.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4319
[Deposit Count/Check]BDS06
Dark Timeout when performing
low-speed moving path down
1. Execute CCIM initialization.
2. Check whether the sensor (BDS06)
detecting the Bundle low-speed moving
path media is polluted when the same
error occurs after initialization.
I4321
[Deposit Count/Check] Fault of
exceeding the limit of media
separation trials.
1. Check the inside of the Bundle(1).
2. Remove the alien materials in the
Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I4331
[Deposit Count/Check]BDS17
Dark fault
1. Check the inside of the Bundle(1).
2. Remove the alien materials in the
Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I4332
[Deposit Count/Check]BDS17
Light fault
1. Check the inside of the Bundle(1).
2. Remove the alien materials in the
Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted