Error Code List Chapter4. Cash & Check In Module
4-70
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I3331
[Entry In/Out]BDS17 Dark fault
1. Check the inside of the Bundle(1).
2. Remove the alien materials in the
Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I3332
[Entry In/Out]BDS17 Light fault
1. Check the inside of the Bundle(1).
2. Remove the alien materials in the
Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I3335
[Entry In/Out]WET NOTE detected 1. Check the inside of the Bundle(1).
2. Remove the alien materials in the
Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I3336
[Entry In/Out]METAL detected
1. Check the inside of the Bundle(1).
2. Remove the alien materials in the
Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I3340
[Entry In/Out] BDS07 Light fault
when preparing for separation of
media.
1. Check the inside of the Bundle(1).
2. Remove the notes and alien materials
in the Bundle(1).
3. If no alien material exists in the
Bundle(1), check and remove the alien
materials in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I334A
[Entry In/Out]Bundle Sub action
Timeout
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I3360
[Entry In/Out]SCM and BC Part
residual fault.
1. BC(3) and SCM(2) Open
2. Remove the notes and alien materials
in the BC, SCM. and Bundle.
3. Check the BC and SCM Half Lock
state.
4. If no alien material exists in the BC
and SCM, check whether the SCM
internal media detection sensors
(FDS01, FDS02, FDS03, FDS04,
FDS05) are polluted.