I9F13
[Retract]Error occurred by the
Return Transport Path( FDS18)
1. Open the BM2(7) and remove the
residual media at the moving path (6)
and Cassette1(14) entry.
2. Execute initialization.
I9F14
[Retract]Error occurred by the
Return Transport Path( NCS07)
1. Check residual media or alien
materials at the Cassette1(14) entry and
remove those.
I9F15
[Retract]Error occurred by the
Return Transport Path( RJS08)
1. Remove the residual media in the
device.
2. Execute initialization.
I9F16
[Retract]Error occurred by the
Return Transport Path( PRS01)
1. Open the third moving path (8) and
then remove the residual media and
alien materials.
2. Check the 3Way-Gate2 operation
state (FDM07)
I9F17
[Retract]Error occurred by the
Return Transport Path( FDS16)
1. Open the BM3 moving path and then
remove the residual media and alien
materials.
2. Check the arrangement state of
banknotes in the RT box.
I9F18
[Retract]Error occurred by the
Return Transport Path( RTS02)
1. Open the BM2(7) and remove the
residual media at the moving path (6, 7,
8, 9).
2. Remove the notes in the Retract Box.
3. Execute initialization.
I9F19
[Retract]Error occurred by the
Return Transport Path( FDS19)
1. Remove the residual media at the
Cassette2 entry (11).
2. Execute initialization.
I9F1A
[Retract]Error occurred by the
Return Transport Path( CCS07)
1. Check residual media or alien
materials at the Cassette2(15) entry and
remove those.
IB0C1
[AutoDimming] Receives
undefined USB CONTROL
command.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
IB0C2
[AutoDimming]A wrong size is
received during USB CONTROL
PIPE communication.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
IB0C3
[AutoDimming]The size of USB
bulk data is 0 or not the multiple of
64.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
IB0CF
[AutoDimming]Fault of transmitting
the same seq of SP.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
IB801
[AutoDimming] A command was
not executed due to a fault which
has occurred while preparing the
main task.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
IB802
[AutoDimming]Main Task force
shut down.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
IB803
[AutoDimming] Receives a
command which has not been
defined in the main task.