Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-187
Code
Problem Description
Troubleshooting
568HG08
Error of available support
country numbers set up during
receiving BCU data write
command in the Withdrawal
Ready .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
568HG09
Error of country-code set up
during receiving BCU data
write command in the
Withdrawal Ready .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
568HG10
Error of no recognition DB for
the country during receiving
BCU data write command in
the Withdrawal Ready .
1. Check the country
2. Download DB again after delecting all
recognition DB
3. Operate to initialize BRM(Recovery)
4. Reboot the system when same error
occurred after initialization
568HG11
Error of no country code set up
during receiving BCU ready
command in the Withdrawal
Ready .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
568HG12
BC spec differs from data write
command paramter during
Withdrawal Ready .
1. Check the BCU specifications.
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initializatio
568HG20
Error to initialize CIS during
receiving BCU ready command
in the Withdrawal Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
568HG21
Error of power on during
receiving BCU ready command
in the Withdrawal Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
568HG22
Error of DD sensor initialization
during receiving BCU ready
command in the Withdrawal
Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
568HG23
Error of set up for DD sensor
DAC during receiving BCU
ready command in the
Withdrawal Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance