Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-297
Code
Problem Description
Troubleshooting
5A07K00
Error occurred by the notes
disorder on the GS703 during
Retract CSM.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5A07M00
Error occurred by the notes
disorder on the GS031 during
Retract CSM.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A07N00
Error occurred by the notes
disorder on the GS032 during
Retract CSM.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A07P00
Error occurred by the notes
disorder on the GS033 during
Retract CSM.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A07Q00
Error occurred by the notes
disorder on the GS034 during
Retract CSM.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A07W00
GS802 error occurred by the
notes disorder on the during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A0DR00
Error of failure to synchronizing
recognition during Retract
CSM.
1. Operate to initialize BRM(Recovery)
5A0DS00
Error of failure to synchronizing
recognition during Retract
CSM.
1. Operate to initialize BRM(Recovery)
5A0DT00
Error of failure to synchronizing
recognition during Retract
CSM.
1. Operate to initialize BRM(Recovery)