Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-346
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5B3J300
RC3 full check failure during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Check the stage status after open the
recycle cassette(C)
5. Check contamination status of the
GS312 sensor.
5B3R100
RC3 message timeout error
during operation ready in the
Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B3R200
RC3 message timeout error
during transation operation in
the Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B3R300
RC3 message timeout error
during postprocessing to
Retract TE Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B3S100
Undefined return value of RC3
during Retract TE.
1. Operate to initialize BRM(Recovery)
5B3S200
Undefined command of RC3
during Retract TE.
1. Operate to initialize BRM(Recovery)
5B40500
GS405 light jam error during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(17)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).
5B41100
GS401 sensor jam during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5B41200
GS402 sensor jam during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance