Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-221
Code
Problem Description
Troubleshooting
573GA00
RC3 solenoid echo error
during Withdarawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Reload the recycle cassette (C) after
removing recycle cassette
4. Replace the cassette when same
error occurs
573GB00
Encoder Sensor(GS307) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Withdarawal.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #3 and
open its door.(C)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS307 works fine if
there is nothing jammed.
573GC00
Encoder Sensor(GS307) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Withdarawal.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #3 and
open its door.(C)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS307 works fine if
there is nothing jammed.
573J200
RC3 empty during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Check the notes remain after Open
the recycle cassette door(C)
5. Fill up the Notes if there are no notes
6. Check whether the sensor is
contaminated if there are Notes.
573K100
Requried separate note count
of RC3 is 0 during Withdrawal.
1. Operate to initialize BRM(Recovery)
573NL00
Case of below is semi OK.
When RC3 setting count is 0
during withdrawal, separation
is set to sop. Actual count is
more than remain count,
remain count is more than
require count..
1. Check RC3 actual count and SPL
screen count.
2. Setting RC3 count match actual
count.
3. Operate to initialize BRM(Recovery)
573R100
RC3 message timeout error
during operation ready in the
Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
573R200
RC3 message timeout error
during transation operation in
the Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
573R300
RC3 message timeout error
during postprocessing of
Withdrawal Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
573RJ00
RC3 message timeout error
during Stop Ready in the
Withdrawal .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization