Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-148
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
548HG12
BC spec differs from data write
command paramter during
Deposit Cancel .
1. Check the BCU specifications.
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initializatio
548HG20
Error to initialize CIS during
receiving BCU ready command
in the Deposit Cancel .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
548HG21
Error of power on during
receiving BCU ready command
in the Deposit Cancel .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
548HG22
Error of DD sensor initialization
during receiving BCU ready
command in the Deposit
Cancel .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
548HG23
Error of set up for DD sensor
DAC during receiving BCU
ready command in the Deposit
Cancel .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
548HG24
Error of encoder set-up mode
during receiving BCU ready
command in the Deposit
Cancel .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
548HG36
Error of recognized mode
during receiving BCU mode
command in the Deposit
Cancel .
1. Check to the recoginzed mode
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
548HG37
Error of transaction setting
during receiving BCU mode
command in the Deposit
Cancel .
1. Check to the transaction setting
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
548R100
BC message timeout error
during operation ready in the
Deposit Cancel.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization