Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-3
Code
Problem Description
Troubleshooting
5102M00
Error occurred by the notes
remained on GS031 during
Deposit Ready .
1. Open the lower unit.
2. Rotate the knob of the Mid Transport
Path.
3. Remove notes and substance in the
Mid Transport Path (13).
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5102N00
Error occurred by the notes
remained on GS032 during
Deposit Ready .
1. Open the lower unit.
2. Rotate the knob of the Mid Transport
Path.
3. Remove notes and substance in the
Mid Transport Path (13).
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5102P00
Error occurred by the notes
remained on GS033 during
Deposit Ready .
1. Open the lower unit.
2. Rotate the knob of the Mid Transport
Path.
3. Remove notes and substance in the
Mid Transport Path (13).
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5102Q00
Error occurred by the notes
remained on GS034 during
Deposit Ready .
1. Open the lower unit.
2. Rotate the knob of the Mid Transport
Path.
3. Remove notes and substance in the
Mid Transport Path (13).
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
510G100
Failure to 3 Way Gate 0
degree mode conversion
during Deposit Ready .
1. Open the upper unit.
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
510G200
Failure to 3 Way Gate 120
degree mode conversion
during Deposit Ready .
1. Open the upper unit.
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
510NC00
Failure to check the last note
at the termination of mid
transport path during Deposit
Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
510R100
Message timeout error during
operation ready in the Deposit
Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
510R200
Message timeout error during
operation ready in the Deposit
Ready .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
510R300
Message timeout error during
postprocessing to Deposit End
Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization