Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-420
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5D91500
RJC GSA05 dark jam error
during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Open the reject cassette(21)
4. Remove notes and substance in the
reject cassette(21)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5D9J100
RJC full detect error during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated or not if a cassette is
empty.
5D9P100
RJC motor error during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Check the stage after open the door
and push the lever
5. Check the sensor.
5D9R100
RJC message timeout error
during operation ready in the
Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D9R200
RJC message timeout error
during transaction operation in
the Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D9R300
RJC message timeout error
during postprocessing to
Initialize Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5DA2Z00
CSM and TE notes remains
semi OK when Initialize.
1. Open the upper unit
2. Open the CSM(1)
3. Remove notes and substance in the
CSM(1)
4. Open the customer service module
(CSM)
5. Rotate a knob of TE(12)
6. Remove notes and substance in the
Rear Transport Path(11)
7. Check whether the sensor is
contaminated or not if there are No
notes or substance
5DAA100
Status of UTC removal before
the operation during Initialize.
1. Open the upper unit
2. Check removal of the cassette not
received(9)
5DAA200
Status of TE open before the
operation during Initialize.
1. Open the upper Unit
2. Check open/close of TE(12)
5DAA300
Status of BMU inter lock
detachment before the
operation error during Initialize.
1. Check Load/Removal of the upper
unit
2. Replace a cherry switch when error
occures