Error Code List Chapter4. Cash & Check In Module
4-42
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I1F02
[Initialize]Error occurred by the
Return Transport Path(FDS02)
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1F03
[Initialize]Error occurred by the
Return Transport Path(FDS03)
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1F04
[Initialize]Error occurred by the
Return Transport Path(FDS04)
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1F05
[Initialize]Error occurred by the
Return Transport Path(FDS05)
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1F06
[Initialize]Error occurred by the
Return Transport
Path(FDS03,FDS04)
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1F07
[Initialize]Error occurred by the
Return Transport Path( BCS01)
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I1F08
[Initialize]Error occurred by the
Return Transport Path( BCS02)
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I1F09
[Initialize]Error occurred by the
Return Transport
Path( BCS01,BCS02)
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I1F0A
[Initialize]Error occurred by the
Return Transport Path( FDS15)
1. Open the BM4 moving path and then
remove the residual media and alien
materials.
I1F0B
[Initialize]Error occurred by the
Return Transport Path( AAS06)
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I1F0C
[Initialize]Error occurred by the
Return Transport Path( AAS05)
1. After opening the BM2(7) moving
path, open the Alignment(4) Guide2 to
remove media and alien materials.
2. Initialize the device.
4. If the same fault continuously occurs
after checking the device, replace the
Alignment(4) Module.
I1F0D
[Initialize]Error occurred by the
Return Transport Path( AAS03)
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I1F0E
[Initialize]Error occurred by the
Return Transport Path( RCS01)
1. Remove the internal media and alien
materials in the Recognition(5).
2. Initialize the device.
3. If the same fault continuously occurs
after checking the device, replace the