Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-71
Code
Problem Description
Troubleshooting
I33D2
[Entry In/Out]Ultrasonic sensor
does not operate.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
3. Check whether the SCM internal
ultrasonic sensor (FDS06) is polluted
when the same error occurs after
rebooting.
I33D3
[Entry In/Out]BC Task Timeout.
1. Check the cable connecting between
Main and BC (Connector CN37).
I33F0
[Entry In/Out]Bundle Task Skip.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I33FF
[Entry In/Out]Bundle Task force
shutdown.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3401
[Entry In/Out]BC Task Skip.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3402
[Entry In/Out]BC Task force
shutdown.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3403
[Entry In/Out]Fault of calling a
undefined command from BC.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3404
[Entry In/Out]Fault of performing a
undefined processing flow at BC.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3405
[Entry In/Out] Fault of exceeding
the limit of retries when BC does
not respond.
1. Check the cable connecting between
Main and BC (Connector CN37).
I3406
[Entry In/Out] BC response
command error.
1. Check the cable connecting between
Main and BC (Connector CN37).
I3407
[Entry In/Out] Abnormal BCC
received by BC.
1. Check the cable connecting between
Main and BC (Connector CN37).
I3501
[Entry In/Out]Fault of calling a
undefined command from Escrow.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3502
[Entry In/Out]Fault of performing a
undefined processing flow at
Escrow.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3503
[Entry In/Out]Escrow entry
(ESS03, ESS04) residual fault
when preparing for media winding
when Escrow has the media
1. Open the Escrow Part(12).
2. Remove the media at the Escrow
Drum residual check (ESS03) and
output check (ESS04) sensor part and
the pollution.
3. Execute CCIM initialization.
I3504
[Entry In/Out]Tape End (ESS07)
detection fault when preparing for
media winding when Escrow has
media.
1. Open the Escrow Part(12).
2. Manually remove media from Escrow.
3. Initialize.