Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-367
Code
Problem Description
Troubleshooting
5BBHB00
RC1 EEPROM data verify
error during Retract TE.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5BBHC00
RC2 EEPROM data verify
error during Retract TE.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5BBHD00
RC3 EEPROM data verify
error during Retract TE.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5BBHE00
RC4 EEPROM data verify
error during Retract TE.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5BBHF00
RC5 EEPROM data verify
error during Retract TE.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5BBHG00
No detect inter lock during RC
EEPROM R/W during Retract
TE.
1. Check the lower unit status of inter
lock
2. Exchange or clean the inter lock
sensor if occur same error
5BBR000
RBU response timeout during
Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5BBR700
RBU response message
timeout error during Retract
TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5BBS000
RBU communication timeout
error during Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5BBS100
RBU connection sequence
error during Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5BBS200
RBU connection MI error
during Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5BUS100
USB sequence number
duplicate error during Retract
TE.
1. Restart over AP-SP
5BUS300
USB command data length
error during Retract TE.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5C6H100
Failure to write CSM EEPROM
during EEPROM R/W.
1. Check CSM EEPROM
2. Cehck CSM EEPROM connection
3. Replace CSM B/D if same error
occures during EEPROM R/W
5C6H200
Failure to read CSM EEPROM
during EEPROM R/W.
1. Check CSM EEPROM
2. Cehck CSM EEPROM connection
3. Replace CSM B/D if same error
occures during EEPROM R/W