Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-28
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
51AAC00
Status of RJC full before the
operation during Deposit
Ready.
1. Open the upper unit
2. Open the Mid Transport Path
3. Remove the reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated if a cassette is empty
51AAD00
Status of UTC1 full before the
operation during Deposit
Ready.
1. Open the upper unit.
2. Open the cassette not received(9).
3. Check the cassette not received(9) is
full
51AAE00
Status of UTC2 full before the
operation during Deposit
Ready.
1. Open the upper unit
2. Open the forge note cassette(10
3. Check the forge note cassette(10) is
full
51AAF00
Status of RC empty before the
operation during Deposit
Ready.
1. Open the upper unit
2. Open the Mid Transport Path
3. Check the residual notes quantity in
the recycle cassettes(A~E)
51AE100
Received operation command
without Initail Info Set during
Deposit Count.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
51AE200
Status on not operation
receiption command during
Deposit Count.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
51AE300
Received execute command
without Read System Info.
during Deposit Count.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
51AE400
Deposit Ready transaction was
executed without Initializing
after power on.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
51AE600
Error to received deposit ready
during TE Button Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
51AEE00
RBU RS485 communication
sequence error during Deposit
Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
51AEF00
RBU RS485 connection line
error during Deposit Ready
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
51AH500
Error to
NVRAM(128denominations)
Read/ Write in the Deposit
Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
51AR100
Message timeout error during
operation ready in the Deposit
Ready .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization