Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-490
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5NBHC00
RC2 EEPROM data verify
error when CST notes count
Read.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5NBHD00
RC3 EEPROM data verify
error when CST notes count
Read.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5NBHE00
RC4 EEPROM data verify
error when CST notes count
Read.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5NBHF00
RC5 EEPROM data verify
error when CST notes count
Read.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5NBHG00
No detect the inter lock when
RC EEPROM R/W during CST
notes count Read.
1. Check the lower unit status of inter
lock
2. Exchange or clean the inter lock
sensor if occur same error
5NBS000
RBU communication timeout
error when CST notes count
Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5NBS100
RBU connection sequence
error when CST notes count
Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5NBS200
RBU connection MI error when
CST notes count Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5NUS100
USB sequence number
duplicated error when CST
notes count Read.
1. Restart over AP-SP
5NUS300
USB command data length
error when CST notes count
Read.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5OS0100
The shutter did not open under
opening shutter
command(MS2 Light). Closed
statue(MS1 Light).
1. Check that some object disturb to
open shutter
2. Check the motor home position
sensor is under the nomal if error still
occures without disturbed object
5OS1100
The shutter did not open under
opening shutter
command(MS2 Light). Half of
open(MS1 Dark).
1. Check that some object disturb to
open shutter
2. Check the motor home position
sensor is under the nomal if error still
occures without disturbed object
5OS3100
The motor home position
sensor(MS1 & MS2) has
problem (MS1 Light & MS2
Dark).
1. error occurred by motor home
position sensor´s problem
2. Check the motor home position
sensor
3.Check defect of MS1 and MS2
5OSSE00
Sequence number duplicated
with open command.
1. Check the detail sequence number of
bulk sending command
5PAE100
Received operation command
without Initial Info Set during
CST notes count Detete.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail