Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-215
Code
Problem Description
Troubleshooting
I8516
[Deposit End] Residual detection
(ESS03) Jam before Escrow Drum
when outputting the media.
1. Open the Escrow Part(12).
2. Remove the ESS03 media and
pollution.
3. Execute CCIM initialization.
I8517
[Deposit End]Light jam at the
Escrow output check sensor
(ESS04) when outputting the
media.
1. Open the Escrow Part(12).
2. Remove the ESS04 media and
pollution.
3. Execute CCIM initialization. 4. Check
the Escrow Drum running motor
(ESM01).
I8518
[Deposit End]Residual media in
the Escrow (ESS01, ESS02) when
preparing for media discharge.
1. Open the Escrow Part(12).
2. Remove the ESS01 and ESS02
media and pollution.
3. Execute CCIM initialization.
I8519
[Deposit End] Escrow Trigger2
(ESS04) is not detected and
timeout occurs when outputting
the media.
1. Open the Escrow Part(12).
2. Remove the ESS04 media and
pollution.
3. Execute CCIM initialization. 4. Check
the Escrow Drum running motor
(ESM01).
I851A
[Deposit End] Residual detection
sensor (ESS03) Jam before
Escrow Drum when outputting the
media.
1. Open the Escrow Part(12).
2. Remove the ESS03 media and
pollution.
3. Execute CCIM initialization.
I851B
[Deposit End]Jam at the Escrow
output check sensor (ESS04)
when outputting the media.
1. Open the Escrow Part(12).
2. Remove the ESS04 media and
pollution.
3. Execute CCIM initialization.
I851C
[Deposit End]Residual media in
the Escrow (ESS01, ESS02) when
preparing for media discharge.
1. Open the Escrow Part(12).
2. Remove the ESS01 and ESS02
media and pollution.
3. Execute CCIM initialization.
I8520
[Deposit End]For Escrow Drum
winding (50ms+2591Step), the
tape start is not light-detected for
50ms continuously, and a fault
occurs when 6s is exceeded.
1. Open the Escrow Part(12).
2. Remove the ESS06 media and
pollution.
3. Check Motor (ESM01)
4. Execute CCIM initialization.
I8521
[Deposit End]For Escrow Drum
winding (50ms+2591Step), the
Drum motor is not stopped and a
fault occurs when a timeout
occurs.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I8522
[Deposit End]For Escrow Drum
winding (50ms+5730Step), the
tape start is not light-detected for
50ms continuously, and a fault
occurs when 6s is exceeded.
1. Open the Escrow Part(12).
2. Remove the ESS06 media and
pollution.
3. Check Motor (ESM01)
4. Execute CCIM initialization.
I8523
[Deposit End]For Escrow Drum
winding (50ms+5730Step), the
Drum motor is not stopped and a
fault occurs when a timeout
occurs.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.