Code
Problem Description
Troubleshooting
53A2P00
Status of remaining notes on
the Return Transport
Path(GS033) before the
operation during Deposit
End .
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
53A2Q00
Status of remaining notes on
the Return Transport
Path(GS034) before the
operation during Deposit
End .
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
53A2W00
Status of remaining notes on
the Return Transport
Path(GS802) before the
operation during Deposit
End .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
53AA100
Status of UTC removal before
the operation during Deposit
End.
1. Open the upper unit
2. Check removal of the cassette not
received(9)
53AA200
Status of TE open before the
operation during Deposit End.
1. Open the upper Unit
2. Check open/close of TE(12)
53AA300
Status of BMU inter lock
detachement before the
operation during Deposit End.
1. Check Load/Removal of the upper
unit
2. Replace a cherry switch when error
occures
53AA400
Status of BMU removal before
the operation during Deposit
End.
1. Check Load/Removal of the upper
unit
53AA600
Status of CSM open before the
operation during Deposit End.
1. Open the upper Unit
2. Check open/close of CSM
3. Check sensor GS011
53AA700
Status of RJC removal before
the operation during Deposit
End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the reject CST(21)
Load/Removal
53AA800
Status of BMD inter lock
detachment before the
operation during Deposit End.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error