Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-253
Code
Problem Description
Troubleshooting
5902G00
Error occurred by the notes
remained on the GS614 during
Customer Change.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5902H00
Error occurred by the notes
remained on the GS618 during
Customer Change.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5902J00
Error occurred by the notes
remained on the GS619 during
Customer Change.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5902K00
Error occurred by the notes
remained on the GS703 during
Customer Change.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5902M00
Error occurred by the notes
remained on the GS031during
Customer Change.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5902N00
Error occurred by the notes
remained on the GS032 during
Customer Change.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5902P00
Error occurred by the notes
remained on the GS033 during
Customer Change.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance