Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-201
Code
Problem Description
Troubleshooting
5705500
Error occurred by the
Transport Path on the GS005
during Withdrawal .
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5705G00
Error occurred by the
Transport Path on the GS614
during Withdrawal .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5705H00
Error occurred by the
Transport Path on the GS618
during Withdrawal .
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5705J00
Error occurred by the
Transport Path on the GS619
during Withdrawal .
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5705K00
Error occurred by the
Transport Path on the GS703
during Withdrawal .
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5706400
Error occurred by the Return
Transport Path(GS004) during
Withdrawal .
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9)
4. Remove notes and substance in the
Rear Transport Path(8)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5706600
Error occurred by the Return
Transport Path(GS006) during
Withdrawal .
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9)
4. Remove notes and substance in the
Rear Transport Path(7)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance