Code
Problem Description
Troubleshooting
5V8HG12
BC spec differs from data write
command paramter during
System Info Read.
1. Check the BCU specifications.
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initializatio
5V8HG20
Error to initialize CIS during
receiving BCU ready command
in the System Info Read .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5V8HG21
Error of power on during
receiving BCU ready command
in the System Info Read .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5V8HG22
Error of DD sensor initialization
during receiving BCU ready
command in the System Info
Read .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5V8HG23
Error of set up for DD sensor
DAC during receiving BCU
ready command in the System
Info Read .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5V8HG24
Error of encoder set-up mode
during receiving BCU ready
command in the System Info
Read .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5V8HG36
Error of recognized mode
during receiving BCU mode
command in the System Info
Read .
1. Check to the recoginzed mode
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
5V8HG37
Error of transaction setting
during receiving BCU mode
command in the System Info
Read .
1. Check to the transaction setting
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
5V8S100
Receive abnormal MI from BC
during System Info Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization