Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-228
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5752500
Error occurred by the notes
remained on the GS505 during
Withdrawal .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5755500
Error occurred by the
Transport Path on the GS505
during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5756500
Error occurred by the Return
Transport Path(GS505) during
Withdrawal .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5757500
Error occurred by the notes
disorder on the GS505 during
Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
575C100
RC5 mis-pickup during
Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check the upper and the Notes