Error Code List Chapter4. Cash & Check In Module
4-126
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I4D34
[Deposit Count/Check]Continuous
note gap disorder error on the
FDS02
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I4D35
[Deposit Count/Check]Continuous
note gap disorder error on the
FDS03
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I4D36
[Deposit Count/Check]Continuous
note gap disorder error on the
FDS04
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I4D37
[Deposit Count/Check]Continuous
note gap disorder error on the
FDS05
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I4D38
[Deposit Count/Check]Continuous
note gap disorder error on the
FDS03,FDS04
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I4D39
[Deposit Count/Check]Continuous
note gap disorder error on the
BCS01
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I4D3A
[Deposit Count/Check]Continuous
note gap disorder error on the
BCS02
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I4D3B
[Deposit Count/Check]Continuous
note gap disorder error on the
BCS01,BCS02
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I4D3C
[Deposit Count/Check]Continuous
note gap disorder error on the
FDS15
1. Open the BM4 moving path and then
remove the residual media and alien
materials.
I4D3D
[Deposit Count/Check]Continuous
note gap disorder error on the
AAS06
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I4D3E
[Deposit Count/Check]Continuous
note gap disorder error on the
AAS05
1. After opening the BM2(7) moving
path, open the Alignment(4) Guide2 to
remove media and alien materials.
2. Initialize the device.
4. If the same fault continuously occurs
after checking the device, replace the
Alignment(4) Module.
I4D3F
[Deposit Count/Check]Continuous
note gap disorder error on the
AAS03
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I4D40
[Deposit Count/Check]Continuous
note gap disorder error on the
RCS01
1. Remove the internal media and alien
materials in the Recognition(5).
2. Initialize the device.
3. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.