Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-342
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5B2J300
RC2 full check failure during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Check the stage status after open the
recycle cassette(B)
5. Check contamination of GS212
sensor.
5B2R100
RC2 message timeout error
during operation ready in the
Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B2R200
RC2 message timeout error
during transaction operation in
the Retract TE Transaction.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B2R300
RC2 message timeout error
during postprocessing to
Retract TE Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B2S100
Undefined return value of RC2
during Retract TE.
1. Operate to initialize BRM(Recovery)
5B2S200
Undefined command of RC2
during Retract TE.
1. Operate to initialize BRM(Recovery)
5B30500
GS305 light jam error during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(16)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).
5B31100
GS301 sensor jam during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5B31200
GS302 sensor jam during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance