Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-301
Code
Problem Description
Troubleshooting
5A1GG00
Encoder Sensor(GS113) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Retract CSM.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS113 works fine if
there is nothing jammed.
5A1GH00
Encoder Sensor(GS113) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS113 works fine if
there is nothing jammed.
5A22500
Error occurred by the notes
remained on the GS205 during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A25500
Error occurred by the
Transport Path(GS205) during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A26500
Error occurred by the Return
Transport Path(GS205) during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A27500
Error occurred by the notes
disorder on the GS305 during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance