Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-418
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5D8HG09
Error of country-code set up
during receiving BCU data
write command in the
Initialize .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
5D8HG10
Error of no recognition DB for
the country during receiving
BCU data write command in
the Initialize .
1. Check the country
2. Download DB again after delecting all
recognition DB
3. Operate to initialize BRM(Recovery)
4. Reboot the system when same error
occurred after initialization
5D8HG11
Error of no country code set up
during receiving BCU ready
command in the Initialize .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
5D8HG12
BC spec differs from data write
command paramter during
Initialize.
1. Check the BCU specifications.
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initializatio
5D8HG20
Error to initialize CIS during
receiving BCU ready command
in the Initialize .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5D8HG21
Error of power on during
receiving BCU ready command
in the Initialize .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5D8HG22
Error of DD sensor initialization
during receiving BCU ready
command in the Initialize .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5D8HG23
Error of set up for DD sensor
DAC during receiving BCU
ready command in the
Initialize .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5D8HG24
Error of encoder set-up mode
during receiving BCU ready
command in the Initialize .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance