Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-249
Code
Problem Description
Troubleshooting
586P300
PP Separate position
movement error during Notes
Out.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
586P400
PP lose return position
movement error during Notes
Out.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
586P500
PP notes out position
movement error during Notes
Out.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
586P600
PP notes alignment error
during Notes Out.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
586P700
PP separate control(during
separating) error during Notes
Out.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
586P800
PP stack control(during
stacking) error during Notes
Out.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
586P900
Error of reverting notes during
Notes Out.
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the knob rotates softly in the
CSM(3)
586PA00
PP preparation stop error
during Notes Out.
1. Operate to initialize BRM(Recovery)
586R100
CSM message timeout error
during Notes Out Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
586R200
CSM message timeout error
during Notes Out Transaction.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
586R300
CSM message timeout error
during postprocessing to Notes
Out Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
58AA100
Status of UTC removal before
the operation during Notes
Out.
1. Open the upper unit
2. Check removal of the cassette not
received(9)