TPM6-DRAIN

quick guide

overview

Power supply

230/400Vac - 50/60Hz

Pilot lights (LED)

Pump running, High level alarm, Maximum current, Minimum current, Timer, Pump alarm

Protections

Overload, Underload, Phase loss, Jammed impeller

Displayed information (4-digit LED display)

Pump consumption, Maximum current, Minimum current, Timer, Alarms, Settings

Pump output

12A maximum (up to 40A with auxiliary contactor)

High level alarm output

5A maximum

Pump alarm output

5A maximum

Maximum current setting

Auto - 0.6...40A (trip in 7 s)

Minimum current setting

OFF - 0.5...40A (trip in 4 s with 20 s starting delay)

Timed dose setting

OFF - 3 min...24 h

Limited run time setting

30 s...30 min

Maximum terminal cross-section

4mm² (power) / 2,5mm² (control)

specifications

connection diagrams

A

B C D

4

2

1

3

E

F G

5

6

Terminals

A. 

Power supply 230/400V input.

B. 

Pump supply output.

C. 

High level alarm output.

D. 

Pump alarm output.

E. 

90dB alarm buzzer output.

F. 

High level alarm float switch 
input.

G. 

Level control input (probes / 
float switches).

H. 

Current transformer input.

Pilot lights

1. 

Pump running.

2. 

High level alarm.

3. 

Overload setting.

4. 

Underload setting.

5. 

Timer setting.

6. 

Pump alarm.

H

Pump 

12A 

max.

dimensions

single-phase basic diagram

(three-phase pump by 

contactor)

phase loss 

active only

Imin  > OFF

Pump 

12A 

max.

Pump 

12A 

max.

Pump 

12A 

max.