Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-522
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5SAH500
Error to
NVRAM(128denominations)
Read, Write during receiving
BCU counterfeil bill table
registration, inquire command.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization.
5SBS000
RBU communication timeout
error when receiving BCU
counterfeil-bill-table
registration/ inquire command
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5SBS100
RBU connection sequence
error when receiving BCU
counterfeil-bill-table
registration/ inquire command
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5SBS200
RBU connection MI error when
receiving BCU counterfeil-bill-
table registration/ inquire
command
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5SUS100
USB sequence number
duplicate error when receiving
BCU counterfeil-bill-table
registration/ inquire command
1. Restart over AP-SP
5SUS300
USB command data length
error when receiving BCU
counterfeil-bill-table
registration/ inquire command
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5T1GB00
Encoder Sensor(GS107) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Module Test.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS107 works fine if
there is nothing jammed.
5T1GC00
Encoder Sensor(GS107) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Module Test.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS107 works fine if
there is nothing jammed.
5T1GG00
Encoder Sensor(GS113) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Module Test.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS113 works fine if
there is nothing jammed.