Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-19
Code
Problem Description
Troubleshooting
I152A
[Initialize]The Escrow Drum hole is
not detected on the home position
(ESS01, ESS02).
.
1. Open the Escrow Part(12).
2. Remove the ESS01 and ESS02
media and pollution.
3. Execute CCIM initialization.
I152B
[Initialize] When both of Escrow
Tape Start (ESS06) sensor and
the End sensor are detected
simultaneously.
1. Open the Escrow Part(12).
2. Remove the ESS06 and ESS07
media and pollution.
3. Execute CCIM initialization.
I152C
[Initialize]When checking the
residual in the Escrow and tape
end is detected so that retry is
made, the number of retries
exceeds the limit.
1. Open the Escrow Part(12).
2. Remove the ESS07 media and
pollution.
3. Execute CCIM initialization.
I152D
[Initialize]After checking the
residual in the Escrow, tape start
is not detected for 100 mm and
14s is exceeded.
1. Open the Escrow Part(12).
2. Remove the ESS01 and ESS02
media and pollution.
3. Execute CCIM initialization.
I152E
[Initialize]The residual media
before the Escrow entry or Drum
is detected (ESS04, ESS03) while
winding the media.
1. Open the Escrow Part(12).
2. Remove the media at the Escrow
Drum residual check (ESS03) and
output check (ESS04) sensor part and
the pollution.
3. Execute CCIM initialization.
I152F
[Initialize]The residual media
before the Escrow entry or Drum
is detected (ESS04, ESS03) while
winding the media.
1. Open the Escrow Part(12).
2. Remove the media at the Escrow
Drum residual check (ESS03) and
output check (ESS04) sensor part and
the pollution.
3. Execute CCIM initialization.
I1530
[Initialize]The residual media
before the Escrow entry or Drum
is detected (ESS04, ESS03) while
outputting the media.
1. Open the Escrow Part(12).
2. Remove the media at the Escrow
Drum residual check (ESS03) and
output check (ESS04) sensor part and
the pollution.
3. Execute CCIM initialization.
I1531
[Initialize]The residual media
before the Escrow entry or Drum
is detected (ESS04, ESS03) while
outputting the media.
1. Open the Escrow Part(12).
2. Remove the media at the Escrow
Drum residual check (ESS03) and
output check (ESS04) sensor part and
the pollution.
3. Execute CCIM initialization.
I1580
[Initialize]Receives a command
which says to unwind the roll of
the Escrow until exceeding the
number of winding media.
1. Check Sensor (Escrow entry (FDS15)
and output check (EES04) sensor)
2. Execute initialization.
I15F1
[Initialize]Escrow Task force shut
down.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I1602
[Initialize]Batch moving stage
down fail.
1. Check whether the reject batch return
stage down detection (RJS07) sensor is
normally running.
2. Check whether the multiple return
clamp motor (RJM01) is running.