Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-409
Code
Problem Description
Troubleshooting
5D5G200
Failure to move stack position
of RC5 PP during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Open the recycle cassette door (E)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem
5D5G400
Failure to upword moving of
PP during RC5 stack roller
retreat movement in the
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Open the recycle cassette door (E)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem
5D5G500
Failure of RC5 stack roller
retreat during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Check the jam removal knob rotates
softly
5D5G600
Exceeds retry count limit of
detecting RC5 stack
roller´s falling back and
avoiding during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Check the jam removal knob rotates
softly
5D5G700
Failure to move RC5 feed
roller to home position during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Check the jam removal knob rotates
softly
5D5G800
Failure to RC5 push pressure
movement during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Check the upper side of the recycle
cassette
5D5GA00
RC5 solenoid echo disorder
error during Initialize .
1. Open the lower unit
2. Open the Mid Transport Path
3. Reload the recycle cassette (E) after
removing recycle cassette
4. Replace the cassette when same
error occurs