Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-497
Code
Problem Description
Troubleshooting
5Q2GB00
Encoder Sensor(GS207) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS207 works fine if
there is nothing jammed.
5Q2GC00
Encoder Sensor(GS207) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS207 works fine if
there is nothing jammed.
5Q2GG00
Encoder Sensor(GS213) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction.
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS213 works fine if
there is nothing jammed.
5Q2GH00
Encoder Sensor(GS213) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS213 works fine if
there is nothing jammed.
5Q2J300
RC2 full check failure during
Retract CSM + TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Check the stage status after open the
recycle cassette(B)
5. Check contamination of GS212
sensor.
5Q2R100
RC2 message timeout error
during operation ready in the
Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q2R300
RC2 message timeout error
during postprocessing to
Retract CSM + TE Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q2S100
Undefined return value of RC2
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
5Q2S200
Undefined command of RC2
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)