Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-503
Code
Problem Description
Troubleshooting
5Q5GB00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
5Q5GC00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
5Q5GG00
Encoder Sensor(GS513) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction.
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS513 works fine if
there is nothing jammed.
5Q5GH00
Encoder Sensor(GS513) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS513 works fine if
there is nothing jammed.
5Q5J300
RC5 full check failure during
Retract CSM + TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Check the stage status after open the
recycle cassette(E)
5. Check contamination status of the
GS512 sensor.
5Q5R100
RC5 message timeout error
during operation ready in the
Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q5R300
RC5 message timeout error
during postprocessing to
Retract CSM + TE Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q5S100
Undefined Return Values of
RC5 during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
5Q5S200
Undefined command of RC5
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
5Q6G100
BP stack position movement
error during Retract CSM + TE.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM