5HASF00
UTC1 received denomination
is not BRM use denomination
when received CST Set notes
count Command.
1. Check the set up denomination
2. Operate to initialize BRM(Recovery)
5HASG00
UTC2 received denomination
is not BRM use denomination
when received CST Set notes
count Command.
1. Check the set up denomination
2. Operate to initialize BRM(Recovery)
5HASH00
Received count coming out
from RC1 is more than Remain
count when received CST Set
notes count Command.
1. Check the set up count
2. Operate to initialize BRM(Recovery)
5HASJ00
Received count coming out
from RC2 is more than Remain
count when received CST Set
notes count Command.
1. Check the set up count
2. Operate to initialize BRM(Recovery)
5HASK00
Received count coming out
from RC3 is more than Remain
count when received CST Set
notes count Command.
1. Check the set up count
2. Operate to initialize BRM(Recovery)
5HASL00
Received count coming out
from RC4 is more than Remain
count when received CST Set
notes count Command.
1. Check the set up count
2. Operate to initialize BRM(Recovery)
5HASM00
Received count coming out
from RC5 is more than Remain
count when received CST Set
notes count Command.
1. Check the set up count
2. Operate to initialize BRM(Recovery)
5HASN00
Received count coming out
from RJC is more than Remain
count when received CST Set
notes count Command.
1. Check the set up count
2. Operate to initialize BRM(Recovery)
5HASP00
Received count coming out
from UTC1 is more than
Remain count when received
CST Set notes count
Command.
1. Check the set up count
2. Operate to initialize BRM(Recovery)
5HASQ00
Received count coming out
from UTC2 is more than
Remain count when received
CST Set notes count
Command.
1. Check the set up count
2. Operate to initialize BRM(Recovery)
5HBH100
RC1 EEPROM read error
when CST Set Notes Count.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5HBH200
RC2 EEPROM read error
when CST Set Notes Count.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5HBH300
RC3 EEPROM read error
when CST Set Notes Count.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures