Code
Problem Description
Troubleshooting
5A01H00
GS618 dark jam error during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove substance in the Rear
Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5A01J00
GS619 dark jam error during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove substance in the Rear
Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5A01K00
GS703 dark jam error during
Retract CSM.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5A01M00
GS031 dark jam error during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove substance in the Mid
Transport Path
4. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5A01N00
GS032 dark jam error during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove substance in the Mid
Transport Path
4. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5A01P00
GS033 dark jam error during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove substance in the Mid
Transport Path
4. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5A01Q00
GS034 dark jam error during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove substance in the Mid
Transport Path
4. Check whether the sensor is
contaminated or not if there are No
notes or substance.