Error Code List Chapter4. Cash & Check In Module
4-104
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I4379
[Deposit Count/Check]2 or more
media are separated at one time.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I43D2
[Deposit Count/Check]Ultrasonic
sensor does not operate.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
3. Check whether the SCM internal
ultrasonic sensor (FDS06) is polluted
when the same error occurs after
rebooting.
I43D3
[Deposit Count/Check]BC Task
Timeout.
1. Check the cable connecting between
Main and BC (Connector CN37).
I43D4
[Deposit Count/Check]Short
media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I43D6
[Deposit Count/Check]Double
notes are detected.
1. Double notes discharge reject code
2. If this case frequently occurs, check
the state of the separation roller in the
Bundle(1).
I43D8
[Deposit Count/Check]Narrow
media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I43F0
[Deposit Count/Check]Bundle
Task Skip.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I43FF
[Deposit Count/Check]Bundle task
force shutdown.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4401
[Deposit Count/Check]BC Task
Skip.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4402
[Deposit Count/Check]BC task
force shutdown.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4403
[Deposit Count/Check]Fault of
calling a undefined command from
BC.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4404
[Deposit Count/Check]Fault of
performing a undefined process
flow from BC.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.