Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-107
Code
Problem Description
Troubleshooting
53ASJ00
Deposit cassette is set Reject
Receipt cassette in the
absence of deposit cassette
during Deposit End
1. Check state of multi Deposit Cassette
error or full
2. Operate to initialize BRM(Recovery)
53BH100
RC1 EEPROM read error
during Deposit End.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
53BH200
RC2 EEPROM read error
during Deposit End.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
53BH300
RC3 EEPROM read error
during Deposit End.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
53BH400
RC4 EEPROM read error
during Deposit End.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
53BH500
RC5 EEPROM read error
during Deposit End.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
53BH600
RC1 EEPROM Write error
during Deposit End.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
53BH700
RC2 EEPROM Write error
during Deposit End.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
53BH800
RC3 EEPROM Write error
during Deposit End.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
53BH900
RC4 EEPROM Write error
during Deposit End.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
53BHA00
RC5 EEPROM Write error
during Deposit End.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
53BHB00
RC1 EEPROM data verify
error during Deposit End.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
53BHC00
RC2 EEPROM data verify
error during Deposit End.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
53BHD00
RC3 EEPROM data verify
error during Deposit End.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization