Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-525
Code
Problem Description
Troubleshooting
5T4GH00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Module Test.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
5T4P300
Module Test, Insufficient
encoder variation of Push
Plate while RC4 PP moving.
1. Inspection of Push Plate Motor,
Cassette Circuit Board, or the
connection cable between the motor
and the board.
5T5GB00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Module Test.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
5T5GC00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Module Test.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
5T5GG00
Encoder Sensor(GS513) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Module Test.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS513 works fine if
there is nothing jammed.
5T5GH00
Encoder Sensor(GS513) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Module Test.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS513 works fine if
there is nothing jammed.
5T5P300
Module Test, Insufficient
encoder variation of Push
Plate while RC5 PP moving.
1. Inspection of Push Plate Motor,
Cassette Circuit Board, or the
connection cable between the motor
and the board.
5T6G100
BP Stack position transfer
error during Module Test.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5T6G200
BP deposit position transfer
error during Module Test.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM