Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-413
Code
Problem Description
Troubleshooting
5D6M100
Stopper Init error during
Initialize.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
5D6M300
Shutter close error during
Initialize.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
5D6M400
Stopper down error during
Initialize.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
5D6M500
Stopper up error during
Initialize.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
5D6M600
Shutter Close error initializing
stopper during Initialize.
1. Open the upper unit
2. Check knob rotates softly in the
CSM(1)
3. Check inside of CSM
5D6P100
PP withdrawal(stack) position
movement error during
Initialize.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5D6P200
PP deposit position movement
error during Initialize.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5D6P300
PP separate position
movement error during
Initialize.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5D6P400
PP lose return position
movement error during
Initialize.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5D6P500
PP notes out position
movement error during
Initialize.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5D6P600
PP notes alignment error
during Initialize.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5D6P700
PP separate control(during
separating) error during
Initialize.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)